Air-Driven Reaction Fans

Rugged, cast aluminum housing and fan blade make these fans ideal for hazardous locations and demanding ventilation projects. The RF design utilizes action-reaction principles; compressed air is discharged through nozzles located at the tip of the fan blades providing extremely efficient, high-volume, low maintenance air movers.

RF-20, RF-24 FEATURES
  • 11,000 to 16,900 cfm (18,689 to 28,713 m3/hr) at 80 psig
  • Use for fresh air supply or fume exhaust
  • Can be carried or rolled to job site
  • Spark resistant cast aluminum housing and fan blade
  • Permanently lubricated bearings
  • Flanges mate with 20-inch (508mm) and 24-inch (610mm) API tank opening

Swing-Out Assembly

Personnel and equipment egress or entrance to tanks and ve
ssels can be achieved quicker, easier and safer with the RF-20/24 and CP-20 Swing-Out. Mounts to standard API 20-inch or 24-inch tank openings. Swing-out gate, constructed of cast aluminum, is held in closed position with industrial strength hook and loop fastener that can be easily opened and closed by pulling or pushing on Swing-Out.

RF-12, RF-16 FEATURES

  • 2,100 to 5,100 CFM (3,566 to 8,665 m3/hr) at 80 psig
  • Use for fresh air supply or fume exhaust
  • Low compressed air consumption
  • Spark-resistant, cast aluminum housing and fan blade
  • Virtually maintenance free
  • Permanently lubricated bearings eliminate line oiler
  • Cast in handles and feet
  • Cast in bead to accept 12-inch and 16-inch duct
  • Bolt holes allow attachment of optional adapter plates

RF-12, RF-16 PERFORMANCE SPECIFICATIONS

Air flow through Flexible Duct at 80 psig (cfm/m3/hr)
Model Duct
Dia.
in
(mm)
Straight Length of Duct
20'
(6m)
30'
(9m)
40'
(12m)
50'
(15m)
100'
(31m)
RF-12 12"
(305)
2,020
(3,433)
1,960
(3,331)
1,910
(3,246)
1,870
(3,178)
1,680
(2,855)
RF-16 16"
(406)
4,850
(8,241)
4,750
(8,071)
4,600
(7,816)
4,550
(7,731)
4,150
(7,052)

RF-12, RF-16 FREE AIR OPERATING DATA

Air flow divided by consumed air = delivery ratio (efficiency)
Model Inlet
Pressure
Air
Consumption
Total
Air Flow
Delivery
Ratio
psig kg/cm2 scfm m3/hr scfm m3/hr
RF-12 80 5.6 61 104 2,140 3,636 35
RF-16 80 5.6 144 246 5,100 8,665 35

RF-20, RF-24 FREE AIR OPERATING DATA

Air flow divided by consumed air = delivery ratio (efficiency)
Model Inlet
Pressure
Air
Consumption
Total
Air Flow
Delivery
Ratio
psig kg/cm2 scfm m3/hr scfm m3/hr
RF-20 60
80
4.2
5.6
160
210
271
357
7,000
11,000
11,893
18,689
59
53
RF-24 60
80
4.2
5.6
324
400
550
680
14,600
16,900
24,805
28,713
45
42
Contact factory for performance through 20-inch and 24-inch 
air duct.

Industrial Fans
Evaporative
Cooling System
  FAQ's
  Common Terms
Contact Us
  Download PDF
  Order CD
 

Customer Service
1-888-268-8726
Toll Free in the U.S.

 

 

Privacy Policy & Terms of Use | Site Feedback