Ideal for
Utility Underground and Light Industrial Confined Space
Ventilation
These
versatile,
rugged, economical ventilators deliver exceptional airflow
in a compact, lightweight design, and their non-corrosive injection molded
housing is virtually indestructible. They are ideal for utility
underground and light manufacturing confined space ventilation,
and are available in a variety of models.
VANEAXIAL
MODELS
- Flame-resistant UL94-V2-rated injection molded housing (5VA is the highest UL flame retardant rating possible)
- Glass-filled, polyester resin,
spark-resistant fan blade
- Accommodates 8-inch flexible
duct
- Optional attachable duct
canister
CENTRIFUGAL
MODELS
Excellent airflow and pressure
performance
- Flame-resistant UL94-V2
injection-molded housing
- Glass-filled, polyester resin spark resistant fan
blade
- Accommodates 8-inch duct on inlet and outlet
ends
- Fan scroll can be positioned
easily at 45 degree, 90 degree and 180 degree discharge
positions
- Available in electric and
gasoline-driven models
HAZARDOUS
LOCATION MODELS
- Housing and components are constructed of special conductive polymers for safe dissipation of static
charges
- Electric motors meet NEC Class 1, Division 1, Group D; Class ll, Division 1,
Groups
E, F, G specifications
- Available in Vaneaxial and Centrifugal
models
VANEAXIAL
MODELS
 |
| Model |
Drive |
Motor |
HP |
Weight |
Free
Air |
| lbs |
kg |
cfm |
m3/hr |
| VAC1 |
Electric
115V/60Hz |
TE |
1/2 |
35 |
16 |
867 |
1465 |
| VAC2 |
Electric
110V/50Hz |
TE |
1/2 |
35 |
16 |
804 |
1358 |
| VAC3 |
Electric
230V/60Hz |
TE |
1/2 |
35 |
16 |
867 |
1465 |
| VAC4 |
Electric
220V/50Hz |
TE |
1/2 |
35 |
16 |
804 |
1358 |
| EV1 |
Electric
115V/60Hz |
TE |
1/4 |
27 |
12 |
1300 |
2197 |
| VEP1 |
Electric
115V/60Hz |
EP |
1/2 |
35 |
16 |
867 |
1465 |
| VEP2 |
Electric
110V/50Hz |
EP |
1/2 |
35 |
16 |
804 |
1358 |
| VEP3 |
Electric
230V/60Hz |
EP |
1/2 |
35 |
16 |
867 |
1465 |
| VEP4 |
Electric
220V/50Hz |
EP |
1/2 |
35 |
16 |
804 |
1358 |
 |
Performance
through 90 degree bend(s) |
| Model |
1-90
degree |
2-90
degree |
3-90
degree |
| cfm |
m3/hr |
cfm |
m3/hr |
cfm |
m3/hr |
| VAC1 |
776 |
1318 |
766 |
1301 |
756 |
1284 |
| VAC2 |
730 |
1240 |
720 |
1223 |
710 |
1206 |
| VAC3 |
776 |
1318 |
776 |
1301 |
756 |
1465 |
| VAC4 |
730 |
1240 |
720 |
1223 |
710 |
1206 |
| EV1 |
730 |
1240 |
659 |
1119 |
602 |
1023 |
| VEP1 |
776 |
1318 |
766 |
1301 |
756 |
1284 |
| VEP2 |
730 |
1240 |
720 |
1223 |
710 |
1206 |
| VEP3 |
776 |
1318 |
766 |
1301 |
756 |
1284 |
| VEP4 |
730 |
1240 |
720 |
1223 |
710 |
1206 |
 |
CENTRIFUGAL
MODELS
 |
| Model |
Drive |
Motor |
HP |
Weight |
Free
Air |
| lbs |
kg |
cfm |
m3/hr |
| CAC1 |
Electric
115V/60Hz |
TE |
1/2 |
35 |
16 |
1014 |
1722 |
| CAC2 |
Electric
110V/50Hz |
TE |
1/2 |
35 |
16 |
845 |
1428 |
| CAC3 |
Electric
230V/60Hz |
TE |
1/2 |
35 |
16 |
1014 |
1722 |
| CAC4 |
Electric
220V/50Hz |
TE |
1/2 |
35 |
16 |
845 |
1428 |
| CEP1 |
Electric
115V/60Hz |
EP |
1/2 |
35 |
16 |
1014 |
1722 |
| CEP2 |
Electric
110V/50Hz |
EP |
1/2 |
35 |
16 |
845 |
1428 |
| CEP3 |
Electric
230V/60Hz |
EP |
1/2 |
35 |
16 |
1014 |
1722 |
| CEP4 |
Electric
220V/50Hz |
EP |
1/2 |
35 |
16 |
845 |
1428 |
| CGM1 |
Gasoline |
N/A |
3 |
42 |
19 |
1058 |
1783 |
 |
Performance
through 90 degree bend(s) |
| Model |
1-90
degree |
2-90
degree |
3-90
degree |
| cfm |
m3/hr |
cfm |
m3/hr |
cfm |
m3/hr |
| CAC1 |
860 |
1461 |
845 |
1436 |
830 |
1410 |
| CAC2 |
717 |
1218 |
704 |
1196 |
692 |
1176 |
| CAC3 |
860 |
1461 |
845 |
1436 |
830 |
1410 |
| CAC4 |
717 |
1218 |
704 |
1196 |
692 |
1176 |
| CEP1 |
860 |
1461 |
845 |
1436 |
830 |
1410 |
| CEP2 |
717 |
1218 |
704 |
1196 |
692 |
1176 |
| CEP3 |
860 |
1461 |
845 |
1436 |
830 |
1410 |
| CEP4 |
717 |
1218 |
704 |
1196 |
692 |
1176 |
| CGM1 |
897 |
1524 |
882 |
1504 |
866 |
1471 |
 |
|
|